Basec - Quality Approved Cables
Inner Visual

Kilflam™ CIC

Cable Standard Designation

Cable Type: Standard
FPL: UL I424
NPLF (150 V): UL I425
FAX 90: CSA C22.2 No.208

Twisted Pair Specification

Conductor Size (AWG) Number of conductors Nominal conductor diameter in (mm) Nominal cable diameter in (mm) Cable weight (lbs/1000 ft) Maximum conductor resistance (ohms/1000 ft) Nominal capacitance (pF/ft) conductor-conductor Nominal capacitance (pF/ft) conductor-shield
Shielded
I8 2 0.040 (1.02) 0.313 (7.95) 48 6.646 24 46
I6 2 0.051 (1.29) 0.329 (8.36) 68 4.177 29 54
I4 2 0.064 (1.63) 0.362 (9.19) 83 2.625 33 61
I2 2 0.081 (2.06) 0.398 (10.00) 115 1.652 40 74

 

     
Shielded
I8 I8/2-1000 0.040 (1.02)
I6 I6/2-1000 0.051 (1.29)
I4 I4/2-1000 0.064 (1.63)
I2 I2/2-1000 0.081 (2.06)
I8 I8/2-1000U I8/2-300U
I6 I6/2-1000U I6/2-300U
I4 I4/2-1000U I4/2-300U
I2 I2/2-1000U I2/2-300U

Approvals

Ordinary Locations
2-hour fire-resistive cable
2-hour fire- resistant cable
*When installed in ¾” minimum EMT (or RMC) conduit utilizing steel set screw fittings

Designed to meet the requirements of UL2196 when tested in conduit. Available in both shielded and unshielded versions.

Low smoke zero halogen insulated fire-rated twisted pair cable for protection of critical fire alarm circuits.

IDH Kilflam™ CIC fire alarm cables are designed to be 2-hour fire-rated to UL 2196 and ULC S139 when installed in conduit and in accordance with the requirements of the relevant U.S. and Canadian codes. IDH Kilflam™ CIC meets the survivability requirements for fire alarms circuits as outlined in the National Fire Alarm Code (NFPA 70), and the Canadian National Building Code. Install in accordance with the details described in Electrical Circuit Protective System (FHIT), System No. 26 of the UL Fire Resistance Directory.

IDH Kilflam™ CIC fire alarm cable connects the data-gathering panels (transponders) throughout the building and the main fire alarm panel.

Flexible IDH Kilflam™ CIC utilises a tubed jacket, making it the easiest cable on the market to terminate – no special tools required.

Applications include the main trunk or “backbone” of multiplex alarm systems in high-rise buildings and institution, and from each data-gathering panel to the point they enter the notification zone being served.

IDH Kilflam™ CIC can be found in the following applications:
High-rise buildings, for fire alarm and voice communication systems.
Hospitals and other institutions where mobility is limited, for emergency communication systems.
Tunnels and subways, for the emergency voice communication system.
Airports, stadiums, hotels, banks, etc.

Cable Construction

Jacket (tubed): Low smoke, zero halogen polyolefin
Colour: Red
Insulation: Silicone rubber
Conductor type: Copper
Insulation voltage rating: 300 V
Utilization voltage: 72 V
Conductor size: 18-12 AWG
Number of conductors: 2
Unshielded cable Binding tape: Glass tape with flame retardant
Shielded cable:
Shield: Al foil
Drain wire: 18-12 AWG tinned copper